The camera found something in the flue. Here is what it means and what the fix costs.
Get a repair quote
Tell us what the inspection report said and which fireplaces it covers. We will reply with the next step and the figures we can give now.
What the camera picture shows
On the screen, a sound clay flue looks like a square tunnel of even tan tiles, each joint a thin straight line. A failed one looks different. A dark crack runs down the face of a tile, or straight across it. A joint between sections has opened into a gap you can see brick through. A tile has slipped sideways so the tunnel steps. Or there are no tiles at all, only rough brick and old mortar where hot gases have been running for decades.
Each of these fails a Level 2 because heat and smoke can reach the brick and, in a worse case, the wood framing around the chimney. In a building, a gap between two flues can also let smoke from one unit drift into the next.
The flue fixes
Most flue findings lead to one of three repairs. A stainless liner fed down from the top and sized to the appliance below suits most wood fireplaces, inserts and gas units. A poured liner formed inside the old flue suits heavily damaged or oddly shaped flues that a rigid liner cannot follow. And a flue that no longer serves anything can be sealed top and bottom instead of relined.
Each of these is priced in writing for that flue, because height, offsets, the appliance and the state of the crown all change the job. The footage from the inspection is what the figure rests on.
- Cracked or broken tiles: relining with stainless or a poured liner
- Open joints between sections: relining, or a poured liner to fill them
- No liner: a new liner sized to the appliance
- Unused flue: sealed at the top and the bottom
The other items that fail an inspection
Water and weather items often appear on the same report. A missing or rusted cap lets rain and animals into the flue. A leak at the chimney shows as staining around the stack or water at the damper. A wide stack with no cricket holds water against the brick on the uphill side. These have set price ranges, listed below.
Crowns, dampers, chase covers, masonry and flashing on its own are written up with their own figures after we have seen them.
Converting instead of repairing
Sometimes the owner of a failed wood fireplace would rather switch to gas than reline for wood. A sealed gas insert set into the current opening, with its own liner run up the flue, solves the liner finding and the fuel change at once. It is listed below so it can be compared with the relining figure.
Either way, the report is updated when the work is done, with footage of the finished flue.
Repair prices we can give now
These items have set ranges. Relining, crowns, dampers, chase covers and flashing on its own are priced in writing after we see them. The cap row is quoted after we measure the flue.
- Camera run on a flue, before or after the fix
- $415
- Leak traced and stopped at the stack
- $590 to $3,550
- Cricket built behind a wide stack
- $470 to $1,065
- Cricket plus new metal at the whole roof joint
- $710 to $1,750
- Sealed gas insert set into the current opening
- $2,950 to $5,900
- Cap fitted over the flue
- Quoted after we measure
Where a fix depends on the footage, the figure comes in writing with the reason for it.
Questions after a failed inspection
Can I still use the fireplace with a cracked flue tile?
We mark that as stop using until it is repaired. Heat and smoke can reach the brick and framing through the crack.
Why is relining not on the price list?
Because the height, the bends in the flue, the appliance and the condition of the crown all change the job. We price it in writing from the footage.
Our report came from another inspector. Can you work from it?
Yes, tell us what it says. We run our own camera before relining so the figure is based on what we have seen.
Is switching to gas cheaper than relining?
It depends on the flue. We write both figures side by side so you can compare.
Do you check the flue again after the repair?
Yes. The finished flue is recorded and added to the report for that fireplace.
Turn the failed report into a list of fixes
Use the contact page to tell us what the inspection found and which fireplaces it covers, and we will send the next step and the figures.
Call (626) 557-0491