The decision is made flue by flue
Owners of fourplexes in Covina often ask for "a Level 2 on the building" or "the basic one for everybody." Neither is usually right. A fourplex is four fireplaces with four histories. One tenant burns every weekend in winter, one has never lit the hearth, one had the old grate swapped for gas logs last year, and one called about smoke drifting into the bedroom. Those four fireboxes do not need the same inspection, and paying for the same one in all four either wastes money or leaves a question unanswered.
The fair way to order it is unit by unit. This guide shows how we split a fourplex between the two levels, and what the order costs.
The two levels, side by side
NFPA 211 sets out three levels of chimney inspection. Two of them cover almost every building we visit.
| Level | What we do | Price |
|---|---|---|
| Level 1 | Firebox, damper, throat, hearth and clearances from inside; crown, cap and roof joint from above | $58 per fireplace |
| Level 2 | All of Level 1, plus a recorded video run down the full liner and a check of attic or crawl space the chimney passes through | $415 per flue |
The third level involves opening up walls or removing parts of the chimney to see behind them. It comes up only when a Level 2 finds something it cannot fully see, and it is quoted in writing for that flue alone.
What sends a flue to Level 2
We move a unit from the $58 line to the $415 line when any of these apply to that unit:
- A change of fuel or appliance. Gas logs set into a former wood firebox, an insert fitted, or a wood unit going back into use after years of gas
- Signs of a chimney fire. Puffed, flaky creosote, a cracked cap, warped damper plate, or a tenant who heard roaring in the flue
- A quake or a hard knock. A stack that rode out a strong shake, or a roof where a tree limb came down against the brick
- A sale or a refinance. The buyer's side will ask what is inside the liner
- A complaint the Level 1 cannot explain. Smoke in the room, a smell in summer, water at the damper
- No record at all. A flue nobody has scoped since the current owner bought the building
If none of these apply, a Level 1 is the right inspection for that unit, and the money saved stays in the repair budget.
A worked example
Take a fourplex on a Covina side street with one brick stack serving units A and B and a second serving C and D.
- Unit A burns wood each winter, no complaints. Level 1, $58.
- Unit B has not been used in years. Level 1, $58, with the damper and cap checked before anyone lights it.
- Unit C had gas logs fitted last year. Level 2, $415, because a liner sized for a wood fire may not suit the new appliance.
- Unit D reported smoke in the bedroom. Level 2, $415, because the cause may be a cracked tile between C and D.
That is two lines at $58 and two at $415. Putting all four units on the camera would add two more $415 lines for flues that show no reason for them, and putting all four on Level 1 would leave the smoke in unit D unexplained. The split order answers every question on the building without paying for footage nobody needs.
What decides the order for your building
Before we quote, we ask which units have had any of the triggers listed above. If you do not know, we start every unit at Level 1 and tell you on the spot which flues should move up to the camera, with the reason written down. Nothing moves up without your approval, and each Level 2 run is its own line on the quote.
Tell us on the form which units changed fuel, had a complaint or were never scoped, and we will send back a split quote for the building, Level 1 and Level 2 lines marked unit by unit.
What the camera finds that the eye does not
On fourplex stacks the scope often turns up things a Level 1 cannot reach. Tiles that shifted during the 1994 quake and opened a gap between two flues. Mortar missing from the joints between liner sections. A clay liner broken partway down where a past chimney fire cracked it. A wythe of brick between two flues that has worn thin, so smoke from one unit drifts into the other. These matter more in a building than in a house, because the problem in one flue can show up as a complaint in the neighbor's unit.
Each finding on the footage is time-stamped and tied to the unit's page in the report, so the owner can show a repair contractor or a buyer exactly where it is.
What the report gives the owner
The report is filed by unit. Each page lists the level done, the findings, our photos or a link to the footage, and a rank for each item: stop using, repair before next winter, or keep watching. A summary at the front shows all four units on one sheet. Repairs carry their own written prices so you can approve them one at a time. If the camera shows a liner that needs replacing, our guide to relining flues in a shared stack explains how that work is quoted.
Fourplexes across the area
Fourplexes and small courts are common in Covina and in older blocks of Baldwin Park, Azusa and Pomona. Many have brick stacks shared between two units, which is why the split order matters so much here. The chimney inspection page and the Level 2 inspection page carry more detail on each visit, and the cost per unit guide shows how larger buildings are priced.
Ready to split the order
If you have the four units and their histories in front of you, reach us through the contact page and we will mark each one Level 1 or Level 2 before the visit.
Booking for a Whole Building?
Roach visits every fireplace on the property in one trip and writes each one up on its own page, with a price beside every fix. Properties in Covina, Azusa, Baldwin Park, Pomona and the rest of the route are booked the same way.